<includeonly>=Assignment Tab=</includeonly> | <includeonly>=Assignment Tab=</includeonly> | ||
The Signal Reader Assignment Wizard can be found under the tab '''Assignment''' and allows the user to create new assignments for signal reader directly on the portal. This page will guide you through the basics of using the wizard. | The Signal Reader Assignment Wizard, also known as '''haf creator''', can be found under the tab '''Assignment''' and allows the user to create new assignments for signal reader directly on the portal. This page will guide you through the basics of using the wizard. | ||
=== Choosing a Signal Source === | === Choosing a Signal Source === | ||
[[File:Choose Signal Source.png|thumb|Choosing a Signal Source|375x375px]] | [[File:Choose Signal Source.png|thumb|Choosing a Signal Source|375x375px]] |
Revision as of 08:17, 29 June 2020
The Signal Reader Assignment Wizard, also known as haf creator, can be found under the tab Assignment and allows the user to create new assignments for signal reader directly on the portal. This page will guide you through the basics of using the wizard.
Choosing a Signal Source
First, you must select a signal source to base your new assignment on. Today, only custom vehicle types can be used for this, see Figure "Choosing a Signal Source". If you would like to edit the Custom Vehicle types or create a new one, this can be done by admins under the administration tab.
When you feel comfortable with which signal source you would like to use, double click it or select it and click Create new assignment.
Creating a new assignment
Now that you have chosen a signal source, you can start creating the assignment. The first tab that you are presented with is the Assignment global settings tab where you can add information about the assignment so that you can easily keep track of what this assignment is about. Creator and creation date are both automatically filled in and cannot be changed because of consistency.
Under the Measurements tab, see Figure "Measurement Setups", you are presented to a table of Measurement Setups and an information window. These measurement setups are the core of a signal reader assignment. They contain Triggers that activate and deactivate on certain conditions provided by the user. Each trigger can contain a Recorder that contains a list of certain signals that will be measured when the start condition for the respective trigger is met. A trigger can also be used to act as a setup switch.
When you feel finished with the assignment you can simply click the Save assignment button in the lower right corner to save the assignment in its current state.
Trigger
To add a trigger to a measurement setup, click the Add trigger button for the respective measurement setup. This will create a new Trigger in the trigger table in the respective measurement setup and the information window will be filled with new settings for this trigger for you to add.
Fill out the start trigger condition for the trigger. This is easiest to do in the Edit expression window that you can get to by clicking one of the Edit buttons. To find a new signal to add a condition for, use the Add signal button. Here, you can browse all signals available for this assignment. Use the dropdown to browse signals from different can-busses and Wice generic internal signals. If you want to browse the signals currently in use in the assignment for the selected signal source, check the Search in assignment box. If you want more information about a signal, select it and click More info. When you have found the signal you want, double click it or select it and click Add signal. Now you can use the Operators list to add a condition for the signal, for example " > 0". When you are satisfied with the start condition, you will notice that the Validate button has a yellow warning symbol on it. This means that the expression is unvalidated, press the button to validate the expression. The buttons icon now either turns red (expression is unvalid) or green (expression is correct). See Figure "Validate Button States" for the different state of the validate button. Click Save to save the expression. The list of operators supported in trigger condition is available here.
A stop trigger condition is not required, but can be supplied to determine when the recording should stop. If the stop condition is not supplied, the settings for the recorder will tell when the recording should stop.
You can use the trigger Setup switch to switch to/run a measurement setup when the start condition is met. Keep in mind though, that the setup switch will not run until all currently started recorders have at least fulfilled their minimum duration. A trigger with a recorder cannot have a setup switch, but the recorder can.
Recorder
There a two types of recorder, SREC (Signal recorder) and DREC (Diagnostics recorder). Choose which one you want with the radio button at the top of the Recorder tab.
Recorder - DREC
DREC (Diagnostics recorder) is used to ask diagnostic questions on the buses and record the answers. The questions to ask are determined by a sequence file that you are asked to upload.
Recorder - SREC
SREC (Signal recorder) is used to record signals on the busses.
SREC - Signals
Click the Add Signal button to open a window to add signals for recording. This window is much like the window for adding signals for the trigger, only differing in the fact that you can select multiple signals in this window. The selected signals for this recorder are shown in the right table, see Figure "Add Signals for Recorder". To add new signals to this table, you can either:
- Double click the signal,
- Drag and drop the signal
- Select the signal and click the right pointing arrow
Click the red symbol to the right of each signal to remove it. When you are done, click Ok to add the signals.
Now that you have added some signals, you can give them each a Skip factor, default 1, which is an integer that determines how often the signal should be recorded/stored when supplied. For example, a skip factor of 1 will record the signal every time it is supplied and a skip factor of 3 will record the signal every third sample.
Recorder - Properties
Under the recorder tab Properties you can select the properties for the recorder, see Figure "Recorder Properties".
Number of shots is an important factor for a recorder. A shot is the term used for a single recording and number of shots is therefore the number of times we should record. A shot is only started when the start trigger condition is met and will continue until any of these events occur:
- The recording fulfills the maximum duration.
- The recording fulfills the minimum duration and the stop trigger condition is met.
- The recording fulfills the minimum duration and a trigger start a setup switch.
- The recording fulfills the minimum duration and another recorder starts a setup switch.
- A setup switch is started manually.
- The assignment is stopped manually.
The recorder Setup switch is started when recorder has performed its number of shots and all other started recorders have at least fulfilled their minimum duration. It is, like the trigger setup switch, used to switch to/run a measurement setup.
You can also select the Pre trigg duration which determines the amount of data that will be saved in the flash before the start trigger condition is met. Range is 0 to 4294967295 (232).
The Post trigg duration is much like the pre trigg duration and determines the amount of data that will be saved after the stop trigger condition is met. Range is 0 to 4294967295 (232).
The Minimum duration determines the minimum amount of data that needs to be recorded before it becomes possible to cancel the recording through either a stop trigger or a setup swtich started by a trigger or another recorder.
The Maximum duration determines, as the name suggest, the maximum amount of data that should be recorded. Range is 0 to 4294967295 (232).
The Unit for the four aforementioned durations can be set to seconds, samples or bytes. If you choose to set them to seconds, the device will use the timestamps of the incoming data to determine the four aforementioned durations.
Editing an assignment
In order to edit an already created assignment navigate to the tab where you choose a signal source and click the View saved assignments button. This will display a window, see Figure "View Assignments", which lists all of the saved assignments created through the wizard, by whom and when it was created. In order to edit an assignment, select it and click Edit and you will start editing it. Simply click Save assignment when you are done and the old version of the assignment will be updated.
Using a portal assignment for a signal reader task
In order to use a portal assignment. Select the WCUs in the Vehicle tab that you want to create the new signal reader assignment for and click new task. Navigate to the Signal reader tab and click the Browse saved assignments button and select the assignment you want to use and click Ok. This assignment will now be used to create the .haf file required by the WCUs to perform the signal reader task.