Difference between revisions of "New features in v2.71"
Line 27: | Line 27: | ||
== Support for DoIP for Active Signals in the Signal Reader Assignment Editor == | == Support for DoIP for Active Signals in the Signal Reader Assignment Editor == | ||
From version 2.71, Signal Reader supports diagnostics over Ethernet/DoIP as well as over CAN. In the Signal Reader Assignment Editor the selection of whether to use CAN or DoIP for Active Signals is done in the Modules tab. | From version 2.71, Signal Reader supports diagnostics over Ethernet/DoIP as well as over CAN. In the Signal Reader Assignment Editor the selection of whether to use CAN or DoIP for Active Signals is done in the Modules tab. For more information about this, see [[Signal Reader Assignment Editor]]. |
Revision as of 14:30, 22 December 2021
Arcos: A new task and module for the use of an Arcos logger.
Arcos task
A new type of task has been added to upload ccmc files that describes what will be measured by a connected Arcos-logger (by Ipetronik). If the file already exists on the Arcos-logger no file need to be uploaded, instead the name of the existing file needs to be supplied. This is to get a representation in the WICE system of a already ongoing measurement. This enables result files to be found in the WICE portal. See Arcos-task.
Arcos module
There is also a new Arcos-module for adjusting the Arcos-configuration for a WCU. The following can be specified:
- Username
- Password
- Front-end number
- Debug level
See Configure the Arcos Module.
Tasks Panel: Sort on and search in more columns
Now the following columns can be sorted on the Search Fields Section of the Tasks Tab:
- Task creator (also searchable)
- Task owner (also searchable)
- Creation date
- Expire date
To learn more about searching read: Search columns with regular expressions
Tasks Panel: Improved panel 'Vehicle Info'
When selecting a row in the tasks panel the button 'View Vehicle' shows a dialog showing what the vehicle looked like at the time when the task was created. Read more here.
Support for selecting XCP or CCP for Area5 assignments.
Area5 read-outs can now be performed using either the CCP protocol over CAN (as before) or the XCP protocol over Ethernet. The selection of whether to use CCP or XCP is done in the Area5 assignment editor for each ECU. Read more here.
Support for DoIP for Active Signals in the Signal Reader Assignment Editor
From version 2.71, Signal Reader supports diagnostics over Ethernet/DoIP as well as over CAN. In the Signal Reader Assignment Editor the selection of whether to use CAN or DoIP for Active Signals is done in the Modules tab. For more information about this, see Signal Reader Assignment Editor.