Difference between revisions of "New features in v2.74"

From WICE Wiki v2.89
Jump to navigation Jump to search
 
(6 intermediate revisions by 2 users not shown)
Line 5: Line 5:
* Portal access
* Portal access


Denoting whether or not the user has access to the M2M-api (programmatic interface) or to the Portal (the graphical website).
Denoting whether or not the user has access to the M2M API (Application Programmatic Interface) or to the Portal (the web-based graphical user interface).


If logged in as an administrator these accesses can be edited for users.
If logged in as an administrator these accesses can be edited for users.
Line 12: Line 12:
After this release there are no dialogs asking about file naming when downloading result files for a task. Hence less actions required before the files can be downloaded.
After this release there are no dialogs asking about file naming when downloading result files for a task. Hence less actions required before the files can be downloaded.


== Read snapshot & Extended Data for DREC in assignment editor ==
== Read snapshot & Extended Data for DREC in Signal Reader assignment editor ==
It is now possible to to get snapshot and extended data in Assignment editor for DREC. If the sequence file has DTC it will be possible to activate this function.  
It is now possible to choose to get snapshot and extended data in Assignment editor for DTCs  read out in a DREC. If the sequence file contains a DTC read-out request (19 02) it will be possible to activate this function.
 
== Unlimited number of shots selectable for recorders in Signal Reader assignment editor ==
Th number of shots can now be set to infinite (unlimited).


== New DAQ information window ==
== New DAQ information window ==
A new window in the assignment editor is added. It can be reached from the modules tab or the measurement setup view by clicking on the button “DAQ Information”. The new window shows each module in every measurement setup that has signals in a recorder and comes from an A2L file. For each module, this window will show signals in it and which DAQ-list it belongs to. If the information about the DAQ list can be parsed from the a2l file, with the selected interface, it will also show how many bytes each list can contain.
A new window in the assignment editor is added. It can be reached from the modules tab or the measurement setup view by clicking on the button “DAQ Information”. The new window shows each module in every measurement setup that has signals in a recorder and comes from an A2L file. For each module, this window will show signals in it and which DAQ-list it belongs to. If the information about the DAQ list can be parsed from the a2l file, with the selected interface, it will also show how many bytes each list can contain.
== MSW validation for MLog tasks ==
It is now possible to enter MSW numbers for Mlog Tasks, to ensure the measurement setup of the Mlog is using the correct description files.
== Signal Reader improvements ==
There are multiple improvements to the Signal Reader module:
* Now properly supports pre-trigged recording of WICE internal signals,
* Supports for an unlimited number of shots in recorders,
* Supports diagnostic recorders (DRECs) using DoIP,
* Handles DTC extended data and shaphots per DREC,
* Enables and disables Ethernet using digital out 4 at MS switches when using DoIP,
* Has a more lenient MSW validation mechanism: if ECU SW numbers read-out using SoH do not match the assignment, validation fails.
* Bugfixes.
== Configurable Label Announcements ==
In the [[The Portal Administrator View#The Labels Tab|Labels tab]] (found under the Administration tab) it is now possible to configure labels to be included in announcements. Configuring label announcements are done in the same dialog as when creating labels or editing existing labels. There are also three new columns for each label row that denote the label announcement settings for that label:
* To be announced
* Only announce with value
* Resource type
This is only accessible to clients with the feature enabled.

Latest revision as of 10:11, 18 March 2022

Users table: Two new columns showing users' access to M2M and the Portal

In the Users tab (found under the Administration tab) there are two new columns for each user row:

  • M2M access
  • Portal access

Denoting whether or not the user has access to the M2M API (Application Programmatic Interface) or to the Portal (the web-based graphical user interface).

If logged in as an administrator these accesses can be edited for users.

Removed dialogs regarding file downloads

After this release there are no dialogs asking about file naming when downloading result files for a task. Hence less actions required before the files can be downloaded.

Read snapshot & Extended Data for DREC in Signal Reader assignment editor

It is now possible to choose to get snapshot and extended data in Assignment editor for DTCs read out in a DREC. If the sequence file contains a DTC read-out request (19 02) it will be possible to activate this function.

Unlimited number of shots selectable for recorders in Signal Reader assignment editor

Th number of shots can now be set to infinite (unlimited).

New DAQ information window

A new window in the assignment editor is added. It can be reached from the modules tab or the measurement setup view by clicking on the button “DAQ Information”. The new window shows each module in every measurement setup that has signals in a recorder and comes from an A2L file. For each module, this window will show signals in it and which DAQ-list it belongs to. If the information about the DAQ list can be parsed from the a2l file, with the selected interface, it will also show how many bytes each list can contain.

MSW validation for MLog tasks

It is now possible to enter MSW numbers for Mlog Tasks, to ensure the measurement setup of the Mlog is using the correct description files.

Signal Reader improvements

There are multiple improvements to the Signal Reader module:

  • Now properly supports pre-trigged recording of WICE internal signals,
  • Supports for an unlimited number of shots in recorders,
  • Supports diagnostic recorders (DRECs) using DoIP,
  • Handles DTC extended data and shaphots per DREC,
  • Enables and disables Ethernet using digital out 4 at MS switches when using DoIP,
  • Has a more lenient MSW validation mechanism: if ECU SW numbers read-out using SoH do not match the assignment, validation fails.
  • Bugfixes.

Configurable Label Announcements

In the Labels tab (found under the Administration tab) it is now possible to configure labels to be included in announcements. Configuring label announcements are done in the same dialog as when creating labels or editing existing labels. There are also three new columns for each label row that denote the label announcement settings for that label:

  • To be announced
  • Only announce with value
  • Resource type

This is only accessible to clients with the feature enabled.